We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

We apply the joint entropy prior to limited view transmission tomography and demonstrate its sensitivity to local optima. We propose to increase robustness by modelling the joint histogram as the sum of a limited number of bivariate clusters. The method is illustrated for the case of Gaussian distributions. This approximation increases robustness by reducing the possible number of local optima in the cost function. The resulting reconstruction prior mimicks the behaviour of the joint entropy prior in that it narrows clusters in the joint histogram, and yields promisingly accurate reconstruction results despite the null space problem. © 2009 IEEE.

Original publication

DOI

10.1109/ISBI.2009.5193296

Type

Conference paper

Publication Date

17/11/2009

Pages

1279 - 1282