We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: This study investigates the enhanced conformality of neutron dose distributions obtainable through the application of intensity modulated neutron radiotherapy (IMNRT) to the treatment of prostate adenocarcinoma. METHODS AND MATERIALS: An in-house algorithm was used to optimize individual segments for IMNRT generated using an organ-at-risk (OAR) avoidance approach. A number of beam orientation schemes were investigated in an attempt to approach an optimum solution. The IMNRT plans were created retrospectively for 5 patients previously treated for prostate adenocarcinoma using fast neutron therapy (FNT), and a comparison of these plans is presented. Dose distributions and dose-volume histograms (DVHs) were analyzed and plans were evaluated based on percentage volumes of rectum and bladder receiving 95%, 80%, and 50% (V(95), V(80), V(50)) of the prescription dose, and on V(60) for both the femoral heads and GM(muscle) group. RESULTS: Plans were normalized such that the IMNRT DVHs for prostate and seminal vesicles were nearly identical to those for conventional FNT plans. Use of IMNRT provided reductions in rectum V(95) and V(80) of 10% (2-27%) and 13% (5-28%), respectively, and reductions in bladder V(95) and V(80) of 12% (3-26%) and 4% (7-10%), respectively. The average decrease in V(60) for the femoral heads was 4.5% (1-18%), with no significant change in V(60) for the GM(muscle) group. CONCLUSIONS: This study provides the first analysis of the application of intensity modulation to neutron radiotherapy. The IMNRT technique provides a substantial reduction in normal tissue dose in the treatment of prostate cancer. This reduction should result in a significant clinical advantage for this and other treatment sites.

Original publication

DOI

10.1016/j.ijrobp.2007.04.040

Type

Journal article

Journal

Int J Radiat Oncol Biol Phys

Publication Date

01/08/2007

Volume

68

Pages

1546 - 1556

Keywords

Adenocarcinoma, Algorithms, Femur Head, Humans, Male, Muscle, Skeletal, Neutrons, Prostatic Neoplasms, Radiation Injuries, Radiography, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Rectum, Seminal Vesicles, Urinary Bladder