We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Purpose: To investigate the influence of changes in α/β ratio (range 1.5-3 Gy) on iso-effective doses, with varying treatment time, in spinal cord and central nervous system tissues with comparable radio-sensitivity. It is important to establish if an α/β ratio of 2 Gy, the accepted norm for neuro-oncology iso-effect estimations, can be used.Methods: The rat spinal cord irradiation data of Pop et al. provided ED50 values for radiation myelopathy for treatment times that varied from minutes to ∼6 days. Analysis using biphasic repair kinetics, allowing for variable dose-rates, provided the best fit with repair half-times of 0.19 and 2.16 hr, each providing ∼50% of overall repair; with an α/β ratio 2.47 Gy (CI 1.5-3.95 Gy). Using the above data set, graphical methods were used to investigate changes in the repair parameters for differing fixed α/β ratios between 1.5 and 3.0 Gy. Two different intermittent dose delivery equations were used to evaluate the implications in a radiosurgery setting.Results: Changes in the α/β ratio (1.5-3.0 Gy) have a minor effect on equivalent doses for radiation myelopathy for treatment durations of a few hours. Changing the α/β value from 2 Gy to 2.47 Gy, modified equivalent single doses by < 1% when overall treatment times ranged from 0.1 to 5.0 hr. Significant changes were only found for treatment times longer than 5-10 hr. These two α/β ratios were also compared in a practical radiosurgery situation, using two different models for estimating BED, again there was no significant loss of accuracy.Conclusions: It is reasonable to use an α/β ratio of 2 Gy for CNS tissue, with the same repair half-times as published in the original publication by Pop et al., in situations where the assessment of the BED in radiosurgery is used with other form of radiotherapy. In radiosurgery, the variation in BED with treatment duration (for a fixed physical dose) is very similar, but absolute BED values depend on the α/β value. In radiosurgery, clinical recommendations obtained using BED calculations using the originally proposed α/β ratio of 2.47 Gy are still appropriate. For calculations involving a combination of radiosurgery and other modalities, such as fractionated radiotherapy, it would be appropriate in all cases to apply a value of 2 Gy, the accepted norm in neuro-oncology, without significant loss of accuracy in the radio-surgical component. This may have important applications in retreatment situations.

Original publication

DOI

10.1080/09553002.2020.1748736

Type

Journal article

Journal

Int J Radiat Biol

Publication Date

28/04/2020

Pages

1 - 7

Keywords

Radiosurgery, biologically effective dose (BED), treatment time, α/β ratio