We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: Our purpose was to demonstrate the use of novel planning techniques in producing high-quality stereotactic radiosurgery (SRS) plans using a standard 5 mm multileaf collimator (MLC) and multiple isocenters delivered clinically at a local institution. METHODS AND MATERIALS: Novel planning techniques consisted of offset isocenter, variable asymmetrical jaws, and Digital Imagine and Communications in Medicine (DICOM) edits to reduce leaf tip transmission, all with the aim of maximizing dose conformity. A local institution clinical cohort was planned (1-4 targets), and plan conformity metrics common to SRS were compared against conformity metrics from selected previous publications comparing Gamma Knife to linear accelerator SRS using high-definition MLC (2.5 mm). Additionally, local institution plan conformity metrics for 2 benchmark SRS planning cases (3 and 7 targets) were compared with metrics from other centers treating SRS clinically in England. Pretreatment quality assurance results, both point dose measurement and film analysis, are presented to demonstrate plan deliverability. RESULTS: Clinical conformity metrics are shown to be comparable to previously published results using either Gamma Knife or linear accelerator with high-definition MLC. Metrics from benchmark planning cases are shown to be comparable and to have better prescription dose conformity than average nationally in England. Pretreatment quality assurance results demonstrate suitable plan deliverability. CONCLUSIONS: SRS planning using standard 5 mm MLC and multiple isocenters produces high-quality treatment plans for a limited number of targets with a high degree of dose conformity and dose fall off when employing novel planning techniques to compensate for MLC leaf size and multiple isocenters.

More information Original publication

DOI

10.1016/j.prro.2020.03.004

Type

Journal article

Publication Date

2020-01-01T00:00:00+00:00

Volume

10

Pages

293 - 300

Total pages

7

Keywords

Algorithms, Humans, Radiosurgery, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted