We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVE: To identify a subgroup of lung cancer plans where the analytical dose calculation (ADC) algorithm may be clinically acceptable compared to Monte Carlo (MC) dose calculation in intensity modulated proton therapy (IMPT). METHODS: Robust-optimised IMPT plans were generated for 20 patients to a dose of 70 Gy (relative biological effectiveness) in 35 fractions in Raystation. For each case, four plans were generated: three with ADC optimisation using the pencil beam (PB) algorithm followed by a final dose calculation with the following algorithms: PB (PB-PB), MC (PB-MC) and MC normalised to prescription dose (PB-MC scaled). A fourth plan was generated where MC optimisation and final dose calculation was performed (MC-MC). Dose comparison and γ analysis (PB-PB vs PB-MC) at two dose thresholds were performed: 20% (D20) and 99% (D99) with PB-PB plans as reference. RESULTS: Overestimation of the dose to 99% and mean dose of the clinical target volume was observed in all PB-MC compared to PB-PB plans (median: 3.7 Gy(RBE) (5%) (range: 2.3 to 6.9 Gy(RBE)) and 1.8 Gy(RBE) (3%) (0.5 to 4.6 Gy(RBE))). PB-MC scaled plans resulted in significantly higher CTVD2 compared to PB-PB (median difference: -4 Gy(RBE) (-6%) (-5.3 to -2.4 Gy(RBE)), p ≤ .001). The overall median γ pass rates (3%-3 mm) at D20 and D99 were 93.2% (range:62.2-97.5%) and 71.3 (15.4-92.0%). On multivariate analysis, presence of mediastinal disease and absence of range shifters were significantly associated with high γ pass rates. Median D20 and D99 pass rates with these predictors were 96.0% (95.3-97.5%) and 85.4% (75.1-92.0%). MC-MC achieved similar target coverage and doses to OAR compared to PB-PB plans. CONCLUSION: In the presence of mediastinal involvement and absence of range shifters Raystation ADC may be clinically acceptable in lung IMPT. Otherwise, MC algorithm would be recommended to ensure accuracy of treatment plans. ADVANCES IN KNOWLEDGE: Although MC algorithm is more accurate compared to ADC in lung IMPT, ADC may be clinically acceptable where there is mediastinal involvement and absence of range shifters.

Original publication

DOI

10.1259/bjr.20190583

Type

Journal article

Journal

Br J Radiol

Publication Date

03/2020

Volume

93