We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVE: To recalculate biological effective dose values (BED) for radio-surgical treatments of acoustic neuroma from a previous study. BEDs values were previously overestimated by only using beam-on times in calculations, so excluding the important beam-off-times (when deoxyribonucleic acid repair continues) which contribute to the overall treatment time. Simple BED estimations using a mono-exponential approximation may not always be appropriate but if used should include overall treatment time. METHODS: Time intervals between isocenters were estimated. These were especially important for the Gamma Knife Model 4C cases since manual changes significantly increase overall treatment times. Individual treatment parameters, such as iso-center number, beam-on-time, and beam-off-time, were then used to calculate BED values using a more appropriate bi-exponential model that includes fast and slow components of DNA damage repair over a wider time range. RESULTS: The revised BED estimates differed significantly from previously published values. The overestimates of BED, obtained using beam-on-time only, varied from 0%-40.3%. BED subclasses, each with a BED range of 5 Gy2.47, indicated that revised values were consistently reduced when compared with originally quoted values, especially for 4C compared with Perfexion cases. Furthermore, subdivision of 4C cases by collimator number further emphasized the impact of scheduled gap times on BED. Further analysis demonstrated important limitations of the mono-exponential model. Target volume was a major confounding factor in the interpretation of the results of this study. CONCLUSIONS: BED values should be estimated by including beam-on and beam-off times. Suggestions are provided for more accurate BED estimations in future studies.

Original publication

DOI

10.1016/j.wneu.2022.12.119

Type

Journal

World Neurosurg

Publication Date

04/2023

Volume

172

Pages

e130 - e143

Keywords

Acoustic neuroma, Biologically effective dose, Brain oedema, Radiation volume related effects, Radiosurgery, Vestibular schwannoma, Humans, Radiosurgery, Neuroma, Acoustic, Radiotherapy Dosage