We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Telepathology utilizing high-throughput static whole slide image scanners is proposed to address the challenge of limited pathology services in resource-restricted settings. However, the prohibitive equipment costs and sophisticated technologies coupled with large amounts of space to set up the devices make it impractical for use in resource-limited settings. Herein, we aimed to address this challenge by validating a portable whole slide imaging (WSI) device against glass slide microscopy (GSM) using lymph node biopsies from suspected lymphoma cases from Sub-Saharan Africa. MATERIAL AND METHODS: This was part of a multicenter prospective case-control head-to-head comparison study of liquid biopsy against conventional pathology. For the portable WSI scanner validation, the study pathologists evaluated 105 surgical lymph node specimens initially confirmed by gold-standard pathology between February and December 2021. The tissues were processed according to standard protocols for Hematoxylin and Eosin (H&E) and Immunohistochemistry (IHC) staining by well-trained histotechnicians, then digitalized the H& E and IHC slides at each center. The digital images were anonymized and uploaded to a HIPAA-compliant server by the histotechnicians. Three study pathologists independently accessed and reviewed the images after a 6-week washout. The agreement between diagnoses established on GSM and WSI across the pathologists was described and measured using Cohens' kappa coefficient (κ). RESULTS: On GSM, 65.5% (n=84) of specimens were lymphoma; 25% were classified as benign, while 9.5% were metastatic. Morphological quality assessment on GSM and WSI established that 79.8% and 53.6% of cases were of high quality, respectively. When diagnoses by GSM were compared to WSI, the overall concordance for various diagnostic categories was 93%, 100%, and 86% for lymphoma, metastases, and benign conditions respectively. The sensitivity and specificity of WSI for the detection of lymphoma were 95.2% and 85.7%, respectively, with an overall inter-observer agreement (κ) of 0.86; 95% CI (0.70-0.95). CONCLUSIONS: We demonstrate that mobile whole slide imaging (WSI) is non-inferior to conventional glass slide microscopy (GSM) for the primary diagnosis of malignant infiltration of lymph node specimens. Our results further provide proof of concept that mobile WSI can be adapted to resource-restricted settings for primary surgical pathology and would significantly improve patient outcomes.

Original publication

DOI

10.1016/j.jpi.2023.100188

Type

Journal article

Journal

J Pathol Inform

Publication Date

2023

Volume

14

Keywords

BL, Burkitt Lymphoma, CAP, College of American Pathologists, DLBCL, Diffuse Large B-cell Lymphoma, GSM, Glass slide microscopy, H&E, Hematoxylin and Eosin staining, HL, Hodgkin’s Lymphoma, IHC, Immunohistochemistry, LMICs, Low-and-middle income countries, Lymphoma diagnosis, NPV, Negative predictive value, PPV, Positive predictive value, Portable whole slide imaging scanner, Resource-limited setting, Validation, WSI, Whole slide imaging